{"product_id":"ledcure-four-band-profiler-uv-radiometer","title":"LEDCure® Four Band Profiler (Four LED Bands with Display, 128 Hz Profile Sampling)","description":"\u003ch3 data-start=\"0\" data-end=\"112\"\u003e\u003cstrong data-start=\"4\" data-end=\"112\"\u003eEIT 2.0™ LEDCure® Profiler — Precision UV LED Radiometer with Profiling for Quantitative Process Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"114\" data-end=\"648\"\u003eThe \u003cstrong data-start=\"118\" data-end=\"169\"\u003eEIT 2.0 LEDCure® Profiler (SAL-B1008 Rev 01.02)\u003c\/strong\u003e is a \u003cstrong data-start=\"175\" data-end=\"226\"\u003ehigh-performance, single-band UV LED radiometer \u003c\/strong\u003epurpose-built for \u003cstrong data-start=\"245\" data-end=\"300\"\u003eobjective irradiance and energy density measurement\u003c\/strong\u003e with \u003cstrong data-start=\"306\" data-end=\"330\"\u003etime-based profiling\u003c\/strong\u003e. Engineered for industrial LED curing applications, the LEDCure Profiler delivers calibrated, \u003cstrong data-start=\"425\" data-end=\"450\"\u003erepeatable UV metrics\u003c\/strong\u003e and \u003cstrong data-start=\"455\" data-end=\"487\"\u003etemporal irradiance profiles\u003c\/strong\u003e essential for process optimization, diagnostics, and quality assurance in production, R\u0026amp;D, and field service environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"650\" data-end=\"653\"\u003e\n\u003ch3 data-start=\"655\" data-end=\"705\"\u003e\u003cstrong data-start=\"659\" data-end=\"705\"\u003eTechnical Excellence in UV LED Measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"707\" data-end=\"1853\"\u003e\n\u003cli data-start=\"707\" data-end=\"1056\"\u003e\n\u003cp data-start=\"709\" data-end=\"1056\"\u003e\u003cstrong data-start=\"709\" data-end=\"745\"\u003eLED-Optimized Spectral Response:\u003c\/strong\u003e Available with a single EIT \u003cstrong data-start=\"774\" data-end=\"812\"\u003eL-Band (L365, L385, L395, or L405)\u003c\/strong\u003e selected at time of order, each band is engineered for narrowband UV LED emission with tight full-width half-maximum (FWHM) and high out-of-band suppression, ensuring precise source-specific measurement. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1057\" data-end=\"1294\"\u003e\n\u003cp data-start=\"1059\" data-end=\"1294\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1082\"\u003eWide Dynamic Range:\u003c\/strong\u003e Supports \u003cstrong data-start=\"1092\" data-end=\"1144\"\u003eoperating ranges from ~200 mW\/cm² up to 40 W\/cm²\u003c\/strong\u003e and cumulative dose up to \u003cstrong data-start=\"1171\" data-end=\"1184\"\u003e250 J\/cm²\u003c\/strong\u003e, covering typical to high-intensity industrial LED curing conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1295\" data-end=\"1567\"\u003e\n\u003cp data-start=\"1297\" data-end=\"1567\"\u003e\u003cstrong data-start=\"1297\" data-end=\"1331\"\u003eHigh Accuracy \u0026amp; Repeatability:\u003c\/strong\u003e Typically \u003cstrong data-start=\"1342\" data-end=\"1359\"\u003e±2 % accuracy\u003c\/strong\u003e within the principal measurement range, with repeatability better than \u003cstrong data-start=\"1431\" data-end=\"1440\"\u003e0.2 %\u003c\/strong\u003e, providing engineering confidence in comparative studies and specification compliance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1853\"\u003e\n\u003cp data-start=\"1570\" data-end=\"1853\"\u003e\u003cstrong data-start=\"1570\" data-end=\"1612\"\u003eTotal Measured Optic Response (TMOR™):\u003c\/strong\u003e EIT’s patented optical calibration methodology incorporates the entire instrument optical path, not just the filter, delivering consistent, unit-to-unit and run-to-run measurements across LED sources. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1855\" data-end=\"1858\"\u003e\n\u003ch3 data-start=\"1860\" data-end=\"1913\"\u003e\u003cstrong data-start=\"1864\" data-end=\"1913\"\u003eProfiler Function — Time-Resolved UV Analysis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1915\" data-end=\"2763\"\u003e\n\u003cli data-start=\"1915\" data-end=\"2213\"\u003e\n\u003cp data-start=\"1917\" data-end=\"2213\"\u003e\u003cstrong data-start=\"1917\" data-end=\"1940\"\u003eTemporal Profiling:\u003c\/strong\u003e With a \u003cstrong data-start=\"1948\" data-end=\"1978\"\u003efixed 128 Hz sampling rate\u003c\/strong\u003e in profiling mode, LEDCure Profiler captures \u003cstrong data-start=\"2024\" data-end=\"2060\"\u003eirradiance as a function of time\u003c\/strong\u003e, enabling engineers to characterize dynamic LED behavior, cycle transitions, and real-time process interactions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2214\" data-end=\"2498\"\u003e\n\u003cp data-start=\"2216\" data-end=\"2498\"\u003e\u003cstrong data-start=\"2216\" data-end=\"2244\"\u003eData Logging \u0026amp; Transfer:\u003c\/strong\u003e Profiling data (irradiance and energy density plus profiles) can be offloaded via \u003cstrong data-start=\"2327\" data-end=\"2370\"\u003eUSB to EIT’s UV PowerView® III software\u003c\/strong\u003e, facilitating \u003cstrong data-start=\"2385\" data-end=\"2457\"\u003epost-run analysis, trend comparison, benchmarking, and documentation\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2499\" data-end=\"2763\"\u003e\n\u003cp data-start=\"2501\" data-end=\"2763\"\u003e\u003cstrong data-start=\"2501\" data-end=\"2539\"\u003eDisplay \u0026amp; On-Device Visualization:\u003c\/strong\u003e The unit clearly reports \u003cstrong data-start=\"2565\" data-end=\"2601\"\u003einstantaneous irradiance (W\/cm²)\u003c\/strong\u003e, \u003cstrong data-start=\"2603\" data-end=\"2633\"\u003eaccumulated energy (J\/cm²)\u003c\/strong\u003e, and a \u003cstrong data-start=\"2641\" data-end=\"2688\"\u003elow-resolution on-screen irradiance profile\u003c\/strong\u003e for quick, at-a-glance assessment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2765\" data-end=\"2768\"\u003e\n\u003ch3 data-start=\"2770\" data-end=\"2806\"\u003e\u003cstrong data-start=\"2774\" data-end=\"2806\"\u003eIndustrial-Grade Engineering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2808\" data-end=\"3438\"\u003e\n\u003cli data-start=\"2808\" data-end=\"3027\"\u003e\n\u003cp data-start=\"2810\" data-end=\"3027\"\u003e\u003cstrong data-start=\"2810\" data-end=\"2834\"\u003eRugged and Portable:\u003c\/strong\u003e Compact, \u003cstrong data-start=\"2844\" data-end=\"2868\"\u003ehandheld form factor\u003c\/strong\u003e with robust aluminum and stainless steel construction suits production floors, service calls, and laboratory settings. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3028\" data-end=\"3225\"\u003e\n\u003cp data-start=\"3030\" data-end=\"3225\"\u003e\u003cstrong data-start=\"3030\" data-end=\"3051\"\u003eExtended Runtime:\u003c\/strong\u003e Powered by \u003cstrong data-start=\"3063\" data-end=\"3096\"\u003etwo replaceable AAA batteries\u003c\/strong\u003e for ~20 hours of continuous operation, ensuring readiness in long measurement campaigns. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3226\" data-end=\"3438\"\u003e\n\u003cp data-start=\"3228\" data-end=\"3438\"\u003e\u003cstrong data-start=\"3228\" data-end=\"3261\"\u003eUser-Selectable Sample Modes:\u003c\/strong\u003e Effective sample settings at \u003cstrong data-start=\"3291\" data-end=\"3314\"\u003e25, 128, or 2048 Hz\u003c\/strong\u003e provide flexible capture strategies for both steady and transient UV LED outputs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3440\" data-end=\"3443\"\u003e\n\u003ch3 data-start=\"3445\" data-end=\"3500\"\u003e\u003cstrong data-start=\"3449\" data-end=\"3500\"\u003eSolution-Oriented Benefits for UV LED Processes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3502\" data-end=\"3610\"\u003eThe LEDCure Profiler is engineered to provide \u003cstrong data-start=\"3548\" data-end=\"3609\"\u003eactionable, quantitative control of UV LED curing systems\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"3612\" data-end=\"4428\"\u003e\n\u003cli data-start=\"3612\" data-end=\"3841\"\u003e\n\u003cp data-start=\"3614\" data-end=\"3841\"\u003e\u003cstrong data-start=\"3614\" data-end=\"3654\"\u003eProcess Verification \u0026amp; Optimization:\u003c\/strong\u003e Establish dose baselines and verify process changes such as \u003cstrong data-start=\"3715\" data-end=\"3777\"\u003eLED height, power output, line speed, or exposure duration\u003c\/strong\u003e with high confidence. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3842\" data-end=\"4032\"\u003e\n\u003cp data-start=\"3844\" data-end=\"4032\"\u003e\u003cstrong data-start=\"3844\" data-end=\"3873\"\u003ePerformance Benchmarking:\u003c\/strong\u003e Compare different LED sources or cure configurations to identify optimal conditions or component degradation trends. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4033\" data-end=\"4219\"\u003e\n\u003cp data-start=\"4035\" data-end=\"4219\"\u003e\u003cstrong data-start=\"4035\" data-end=\"4060\"\u003eMulti-Array Analysis:\u003c\/strong\u003e Isolate and evaluate \u003cstrong data-start=\"4082\" data-end=\"4112\"\u003eindividual LED performance\u003c\/strong\u003e in multi-array systems for precise tuning and quality assurance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4220\" data-end=\"4428\"\u003e\n\u003cp data-start=\"4222\" data-end=\"4428\"\u003e\u003cstrong data-start=\"4222\" data-end=\"4255\"\u003eDocumentation \u0026amp; Traceability:\u003c\/strong\u003e Use \u003cstrong data-start=\"4260\" data-end=\"4290\"\u003eUV PowerView® III software\u003c\/strong\u003e to archive and export profiling data for SPC programs, audit trails, and regulatory compliance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4430\" data-end=\"4433\"\u003e\n\u003cp data-start=\"4435\" data-end=\"4727\"\u003e\u003cstrong data-start=\"4435\" data-end=\"4464\"\u003eEIT 2.0 LEDCure® Profiler\u003c\/strong\u003e delivers engineering-grade UV LED measurement and profiling within a rugged, portable platform — enabling industrial teams to quantify, optimize, and control high-performance LED curing processes with measurable precision.\u003c\/p\u003e","brand":"EIT 2.0","offers":[{"title":"Default Title","offer_id":43268976410702,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/_cdns\/s\/files\/1\/0602\/9498\/7854\/files\/LEDCure_Four_Band_Profiler.jpg?v=1766973410","url":"https:\/\/shop3.blazeasia.com\/products\/ledcure-four-band-profiler-uv-radiometer","provider":"Blaze Technology Pte Ltd","version":"1.0","type":"link"}